The Star/Delta starter is manufactured from three contactors, a timer and a thermal Now Motor terminal connection change from star to delta connection. .. it allowed copying or downloading what I published in PDF now and only lets print it. PDF | When a three-phase squirrel-cage induction motor is to be started with star/delta-connection stator windings with delta as the nominal. STAR DELTA connection Diagram and Working myavr.info - Free download as Word Doc .doc /.docx), PDF File .pdf), Text File .txt) or read online for free.


Author:ELMA PECINOUSKY
Language:English, Spanish, German
Country:Chile
Genre:Technology
Pages:578
Published (Last):22.12.2015
ISBN:681-5-56563-995-3
ePub File Size:17.87 MB
PDF File Size:9.48 MB
Distribution:Free* [*Regsitration Required]
Downloads:47214
Uploaded by: LOUIS

This paper analyses whether any differ- ences in behaviour arise due to an induction motor being star or delta connected when supplied by a current source . myavr.info overview In this type of transformer connection, then primary is connected in star. When a three-phase motor is started on the Star-Delta method it means that, when In the star connection this is achieved by connecting two windings in series.

Three-pole thermal overcurrent release 1 No. Fuse elements or automatic cut-outs for the main circuit 3 Nos.

Fuse element or automatic cut-out for the control circuit 1No. Power Circuit of Star Delta Starter The main circuit breaker serves as the main power supply switch that supplies electricity to the power circuit. In operation, the Main Contactor KM3 and the Star Contactor KM1 are closed initially, and then after a period of time, the star contactor is opened, and then the delta contactor KM2 is closed.

Difference Between Star and Delta Connection

The control of the contactors is by the timer K1T built into the starter. The Star and Delta are electrically interlocked and preferably mechanically interlocked as well. Power circuit of Star-Delta starter In effect, there are four states: The star contactor serves to initially short the secondary terminal of the motor U2, V2, W2 for the start sequence during the initial run of the motor from standstill.

This provides one third of DOL current to the motor, thus reducing the high inrush current inherent with large capacity motors at startup. Controlling the interchanging star connection and delta connection of an AC induction motor is achieved by means of a star delta or wye delta control circuit.

The control circuit consists of push button switches, auxiliary contacts and a timer. This sequence happens in a friction of time. After pushing the ON push button switch, the auxiliary contact of the main contactor coil 2 which is connected in parallel across the ON push button will become NO to NC, thereby providing a latch to hold the main contactor coil activated which eventually maintains the control circuit active even after releasing the ON push button switch.

Now Motor terminal connection change from star to delta connection. Thus, the delta contactor coil cannot be active when the star contactor coil is active, and similarly, the star contactor coil cannot also be active while the delta contactor coil is active.

The control circuit above also provides two interrupting contacts to shutdown the motor. The OFF push button switch break the control circuit and the motor when necessary. The thermal overload contact is a protective device which automatically opens the STOP Control circuit in case when motor overload current is detected by the thermal overload relay, this is to prevent burning of the motor in case of excessive load beyond the rated capacity of the motor is detected by the thermal overload relay.

Star-Delta Connection of Transformer

At some point during starting it is necessary to change from a star connected winding to a delta connected winding. Power and control circuits can be arranged to this in one of two ways — open transition or closed transition. What is Open or Closed Transition Starting 1. Open Transition Starters Discuss mention above is called open transition switching because there is an open state between the star state and the delta state.

In open transition the power is disconnected from the motor while the winding are reconfigured via external switching.

When a motor is driven by the supply, either at full speed or at part speed, there is a rotating magnetic field in the stator. This field is rotating at line frequency. The flux from the stator field induces a current in the rotor and this in turn results in a rotor magnetic field.

STAR DELTA connection Diagram and Working principle.docx

When the motor is disconnected from the supply open transition there is a spinning rotor within the stator and the rotor has a magnetic field. Due to the low impedance of the rotor circuit, the time constant is quite long and the action of the spinning rotor field within the stator is that of a generator which generates voltage at a frequency determined by the speed of the rotor.

When the motor is reconnected to the supply, it is reclosing onto an unsynchronized generator and this result in a very high current and torque transient. The magnitude of the transient is dependent on the phase relationship between the generated voltage and the line voltage at the point of closure can be much higher than DOL current and torque and can result in electrical and mechanical damage.

Open transition starting is the easiest to implement in terms or cost and circuitry and if the timing of the changeover is good, this method can work well.

Open State: This type of operation is called open transition switching because there is an open state between the star state and the delta state. The Main contractor is closed and the Delta and Star contactors are open. There is voltage on one end of the motor windings, but the other end is open so no current can flow.

The motor has a spinning rotor and behaves like a generator. Delta State: The Main and the Delta contactors are closed.

Related Interests

The Star contactor is open. The motor is connected to full line voltage and full power and torque are available 2. This requires the use of a fourth contactor and a set of three resistors. The resistors must be sized such that considerable current is able to flow in the motor windings while they are in circuit.

The auxiliary contactor and resistors are connected across the delta contactor. In operation, just before the star contactor opens, the auxiliary contactor closes resulting in current flow via the resistors into the star connection. Once the star contactor opens, current is able to flow round through the motor windings to the supply via the resistors.

These resistors are then shorted by the delta contactor. If the resistance of the resistors is too high, they will not swamp the voltage generated by the motor and will serve no purpose. In closed transition the power is maintained to the motor at all time. This is achieved by introducing resistors to take up the current flow during the winding changeover. A fourth contractor is required to place the resistor in circuit before opening the star contactor and then removing the resistors once the delta contactor is closed.

These resistors need to be sized to carry the motor current. In addition to requiring more switching devices, the control circuit is more complicated due to the need to carry out resistor switching In close transition there are four states: OFF State.

The neutral point allows both types of loads single phase or three phases to be met. Large unbalanced loads can be handled satisfactory. The Y-D connection has no problem with third harmonic components due to circulating currents inD.

It is also more stable to unbalanced loads since the D partially redistributes any imbalance that occurs. The delta connected winding carries third harmonic current due to which potential of neutral point is stabilized.

Some saving in cost of insulation is achieved if HV side is star connected.

But in practice the HV side is normally connected in delta so that the three phase loads like motors and single phase loads like lighting loads can be supplied by LV side using three phase four wire system. If it is required to connect phase-to-ground loads to this system a grounding bank is connected to the system, as shown in Figure This system a grounding bank is connected to the system, as shown in Figure.

Note that the connected winding is not connected to any external circuit in Figure. Note that the grounding bank does not supply any real power to the load; it is there merely to provide a ground path.

All the power required by the load is supplied by two phases of the ungrounded supply Disadvantages of Star-Delta Connection: In this type of connection, the secondary voltage is not in phase with the primary.

Hence it is not possible to operate this connection in parallel with star-star or delta-delta connected transformer. One problem associated with this connection is that the secondary voltage is shifted by with respect to the primary voltage. This can cause problems when paralleling 3-phase transformers since transformers secondary voltages must be in-phase to be paralleled.Thanks for bringing this up.

In a three phase circuit, there are two types of connections. Dhval Vora Nov 08, A Dual starter connects the motor terminals directly to the power supply.

Good,but carefully marked cable correctly as in V2,W2. Paul Coho. What is the roll of timer. The delta connected winding carries third harmonic current due to which potential of neutral point is stabilized.

KIMBERLEY from Kansas
Look over my other posts. I am highly influenced by biathlon. I do relish exploring ePub and PDF books cheerfully .